Basic Info.
Type
Power Network Combined Surge Protective Device
Structure
Valve Type Arrester
Installation
Tandem Arrester
Certification
ROHS, ISO9001
Specification
106mmx58mmx35mm
Product Description
Product introductionOmldeen Power network combined surge protector (also known as: power network two in one lightning arrester, power network two in one lightning arrester, power network two in one surge protector) is designed according to IEC and GB standards. It is mainly used for power supply of various weak current equipment, security equipment, telecommunication equipment, network equipment and lightning electromagnetic of 100m network signal line Pulse (LEMP) protection is an integrated multi-functional surge protector.
Functional features1. Maximum current capacity: 20KA (8 / 20 μ s), the power line adopts two-stage composite balance safest line, AC can not be divided into zero / fire line, zero / fire line can be connected randomly (DC needs to be divided into positive and negative poles), differential mode (line to line) and common mode (line to ground) full mode protection, low residual voltage, especially suitable for outdoor equipment, where lightning energy is large and residual voltage value is strict.
2. Two stage series compound protection is also used in the network line, differential mode (line to line) and common mode (line to ground) full mode protection, with low residual voltage and long service life;
3. It can effectively prevent equipment damage caused by the instantaneous increase of potential difference between power supply and network lines;
4. The integrated structure is adopted to minimize the volume and occupy no space under the condition of conforming to relevant parameters;
5. Power supply surge protection port with LED failure indication (green: normal; off: failure);
6. The power supply terminal adopts E-type terminal, which meets the requirements of vibration test. The vibration test does not disconnect, which avoids the disadvantages of plug-in type terminal. Easy to install.
technical parameterProduct name | Combined surge protector for power network |
SPD category | Composite SPD |
SPD function | It has the functions of voltage limiting, current limiting and isolation |
model | OMPS-E12/2 |
type | Power Supply | network |
Nominal operating voltage | 12v | 5v |
Maximum continuous operating voltage | 18v | 8v |
Nominal load current | 5A | 500mA |
Nominal discharge current(8/20μS) | 5KA |
Maximum discharge current (8 / 20 μ s) | 10KA |
Power supply protection level | ≤36V (8/20μs) | ≤20V x-x(1.2/50μs) |
Response time | ≤25ns | ≤1ns |
transmission speed | -- | 100M bps |
insertion loss | -- | ≤0.3db |
Interface type | Terminal block | RJ45 |
Installation and wiring specifications | 2.5mm² | -- |
Failure indication | Green: normal Extinguish: failure | -- |
overstressed fault mode | SPD voltage limiting part of the network side of the internal open circuit, the line does not run, but the equipment is still open circuit protection |
temperature range | -40ºC…+85ºC |
Installation mode | Wall fixed or horizontal fixed (placed) |
Dimensions | 106mmx58mmx35mm |
Shell material | aluminium alloy |
Protection level | IP20 |
Test standard | GB18802.1 GB/T 18802.21 |
Installation method of lightning arrester1. The lightning arrester is installed in series in front of the protected equipment port (the "input" identification terminal is connected to the line, and the "output" identification end is connected with the protected camera), and the PE terminal is connected to the lightning protection grounding grid.
2. Line terminal connection method (power supply part): AC power supply: both ends shall be connected with "L1-L1" and "l2-l2" respectively, without dividing zero live line;DC power supply: both ends should be connected with "L1-L1" and "l2-l2". DC is divided into positive and negative poles. The positive pole is connected to L1, and the negative pole is connected to L2. Do not connect it wrong.
3. RJ45 network signal line connection method: Series installation, RJ45 crystal head can be directly inserted. Two
4. The section of grounding wire should be ≥ 4mm and as short as possible. The installation of the lightning protection product requires that the grounding resistance is less than 4 ohm, and the lightning protection performance is the best when the grounding wire and grounding resistance are qualified.
5. The lightning arrester is free of maintenance. The working condition of arrester should be checked and recorded in time after thunderstorm.
FAQ
Q: Are you a factory or a trade company?
A: We are the factory.
Q: Where are your products distributed?
A: Our products are distributed all over the world, Main market are Europe, North America, the United Arab Emirates, Africa and so on.
Q: Can I have a sample?
A: Yes, but according to our company's policy, we provided free samples, while you should pay the freight fee; the sample can be delivered by TNT/DHL/UPS/FEDEX.
Q: Which port is the nearest from you?
A: Guangzhou port or Shenzhen Port or Hong Kong port.
Q: What's your lead time?
A: Sample lead time: 3~5 working days. Mass production: usually 10~30days.
For big orders, honestly, it depends on the order quantity and designs.
Q: When can I get the price?
A: We usually quote within 24 hours after we get your inquiry. If you are very urgent to get the price, please call us or tell us in your email so that we will regard your inquiry as priority.
Q: Can you do the design for us?
A: Yes, we have a professional team having rich experience in molding design, electrical system developing and manufacturing. Please just tell us your ideas and we will help you to carry out your ideas into a perfect artwork. You can pay for the molding fee and own the mold by yourself or we can cooperate on the molding.
Q:How to pay?
A: We accept T/T, Paypal, Western union, L/C, Trade Assurance
Address:
8/F, Building 6, Intelligent Manufacturing Industrial Park, Pingshan High-Tech Zone, No. 2 Hetian Road, Pingshan District, Shenzhen, Guangdong, China
Business Type:
Manufacturer/Factory
Business Range:
Electrical & Electronics, Industrial Equipment & Components, Instruments & Meters, Security & Protection
Management System Certification:
ISO 9001
Company Introduction:
Shenzhen omrdon Technology Co., Ltd. is located in the forefront of science and technology in Shenzhen, China. It is a high-tech lightning protection enterprise specializing in theoretical research on lightning electromagnetic pulse (LEMP) overvoltage protection technology and lightning protection product research, production and sales.
The company has "OMLDEEN" independent brand, the production and sales of surge protection device (SPD, surge protection device) power lightning protection device, power supply lightning protection box, signal lightning protection device, antenna feeder lightning protection device, lightning rod and other lightning protection products. The products are widely used in telecommunications, medical, aviation, security, finance, securities, transportation, petrochemical, photovoltaic solar energy, wind power and meteorology and other fields.
The company has its own workshop and many years of lightning protection product development experience of engineering and technical personnel, can provide a variety of differentiated OEM / ODM manufacturing services for different needs of customers.
The company adhering to the "professional innovation, sustainable service" business philosophy, to provide you with the best quality lightning protection products and solutions "Omrdon" products with stable and reliable quality and perfect after-sales service have won the trust of customers at home and abroad.